Miller Electric 452 Manuel d'utilisateur Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
9
2
1
6
5
8
7
3
4
200
400
300
600
800
1000
1200
50 60 70 80 90 1004010 15 2520 30
% DUTY CYCLE
WELDING AMPS
DUTY CYCLE CHART VOLT/AMP CURVE CC
RATED OUTPUT
SMAW
ARC FORCE
SMAW
GTAW
ARC FORCE
SMAW
MIN
MAX MAX
MIN
700
6005004003002001000
0
20
10
30
40
50
60
70
80
DC AMPS
DC VOLTS
Performance Data
Control Panel
Gold Star
®
452/602 Specifications
(Subject to change without notice.)
1. Arc Force (DIG) Control
2. Polarity Selector Switch*
3. Output Switch (Contactor)
4. Remote Amperage Control Switch
5. Hot Start Switch
6. Digital Meters (Optional)
7. Amperage Adjustment Control
8. Power Switch with Indicator Light
9. High Temperature Shutdown Light
3
Rated Output
450 A at 38 VDC,
60% Duty Cycle
Amperage
Range
20590 A
Max. Open-
Circuit Voltage
72 VDC
Amps Input at Rated Output, 50/60 Hz
200 V 230 V 380 V 400 V 440 V 460 V 575 V KVA KW
102 89 54 51 47 45 36 35.5 23.3
Dimensions
H: 30 in (762 mm)
including lift eye
W: 23 in (585 mm)
D: 38 in (966 mm)
including strain relief
Net
Weight
404 lb
(183 kg)
*Note: Polarity Selector Switch is not standard on 602 model.
Vue de la page 2
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire