SECTION 4 INTRODUCTION
4-1. Specifications
Type of
Input Power
Welding Power
Source Type
Wire Feed Speed
Wire Diameter
Range
Welding
Circuit Rating
IP
Rating
Overall
Dimensions
Weight
24 Volts AC
Single-Phase
10 Amperes
50/60 Hertz
Constant Voltage
(CV)
DC With 14-Pin
And Contactor
Control
Standard: 50 To 780 ipm
(1.2 To 19.8 mpm)
Optional High Speed:
92 To 1435 ipm
(2.3 To 36.4 mpm)
Optional Low Speed:
19 to 300 ipm
(0.4 to 7.6 mpm)
Max Spool Weight:
60 lb (27 kg)
(See Section 5-6)
Max Spool Capacity:
18 in. (457 mm)
100 Volts,
750 Amperes,
100% Duty
Cycle
IP 21S Length: 27 in.
(686 mm)
Width: 12-1/2 in.
(318 mm)
Height: 14 in.
(356 mm)
45 lb
(20.4 kg)
SECTION 5 INSTALLATION
5-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF)
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 609741 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S The EMF assessment on this equipment was conducted at 0.5 meter.
S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
B. Information On Electromagnetic Compatibility (EMC)
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
ce-emc 3 2010-10
5-2. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.