Miller Electric Dimension 1000 Manuel d'utilisateur Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
OM-2223 Page 23
4-12. Electrical Service Guide
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
60 Hz
Input Voltage 230 460 575
Input Amperes At Rated Output 180 90 72
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay
2
225 110 90
Normal Operating
3
250 125 110
Min Input Conductor Size In AWG
4
3/0 3 4
Max Recommended Input Conductor Length In Feet (Meters)
204
(62)
337 (103) 438 (134)
Min Grounding Conductor Size In AWG
4
4 6 6
Reference: 2005 National Electrical Code (NEC)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
4-13. Placing Jumper Links
Ref. 802 295
Tools Needed:
3/8 in
2
Do not overtighten
jumper link nuts.
1
! Disconnect and lockout/tag-
out input power before
installing or moving jumper
links.
Check input voltage available at
site.
1 Jumper Link Label
Check label only one is on unit.
2 Jumper Link
Move jumper links to match input
voltage, and label on unit.
Close and secure access door, or
go on to Section 4-14.