Miller Electric Remote Operator Interface Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
7
1
2
6
5
3
4
7
8
9
Control Panels
1. USB Connection A (Host)
2. Power Switch
3. Wire Feed Speed Sensor Conn. (Optional)
4. Gas Flow Sensor Connection (Optional)
5. 115 VAC, 10 A Duplex Receptacle
6. Circuit Breakers
7. Ethernet Connector A
8. Ethernet Connector B
9. Network Feeder Connector
1. Voltage/Arc Adjust Display Meter
2. Program Display
3. Program # Select
4. Process Setup Button
5. Control Knob
6. Trigger Receptacle
7. On/Off Switch
8. Voltage/Arc Adjust Button
9. Wire Feed Speed/Arc Control Setup Button
10. Wire Speed/Amperage Display Meter
11. Feeder Setup Button
12. Jog/Purge Switch
Front Panel Rear Panel
Program
Process
Wire Type
Gas Type
Volts Time Arc Adjust
WFS Amps Arc Ctl
Process Set Up
Adjust
Feeder Set Up
Trigger Hold
Trigger Control
Sequence
5
4
7
6
3
2
1
8
9
11
12
10
Axcess E Feeder and
Remote Operator Interface (ROI E)
Capabilities
Dual Schedule Toggle between two program
pairs (e.g. 1,2 – 3,4 – 5,6 – 7,8).
4T When trigger is released, output will
operate at different weld parameters.
Trigger Program Select (TPS) Provides the
ability to access any of the Multi-MIG
®
processes or any of the eight active programs.
Trigger Dual Schedule (TDS) When activated
allow selection between predetermined program
pairs (e.g. 1,2 – 3,4 – 5,6 – 7,8).
Trigger Hold (TH) When activated, allows gun
trigger release and continuous welding until
trigger is pulled again.
Carbon Arc Gouging (CAC-A) Can be activated.
Sequence
Preflow: 0.1 10.0 seconds
Start Power: 0.1 10.0 seconds
Crater: 0.1 10.0 seconds
Postflow: 0.1 10.0 seconds
Arc Adjust Arc length (Trim)
Arc Control Arc force or focus (SharpArc
®
)
Process Selection Accu-Pulse
®
,
Accu-Curve
, Pulsed MIG, MIG, Metal-Cored
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12

Commentaires sur ces manuels