technical reference
334 Synrad Firestar t-Series operator’s manual
t100 general specifications
Table 3-9 Firestar t100 general specifications
Parameter Firestar t100
Output Specifications
Wavelength
..................................................10.57–10.63 microns
Power Output
1, 2, 3
..........................................100 Watts
Power Stability
4
.............................................± 7%
Mode Quality .................................................M
2
< 1.2
Beam Waist Diameter (at 1/e
2
)
5
.....................2.2 ±0.2 mm
Beam Divergence, full angle (at 1/e
2
)
5
...........< 7 mrad
Ellipticity .......................................................< 1.2
Polarization ...................................................Linear, vertical
Extinction Ratio ............................................> 100:1
Rise Time ......................................................< 75 µs
Modulation (Optical response) ....................up to 25 kHz
Input Specifications
Power Supply
Voltage ...................................................30 VDC
Maximum Current .................................75 A
Command Input Signal
Voltage ...................................................+3.5 to +6.7 VDC
Current ..................................................10 mA @ +6.7 VDC
Frequency
6
..............................................DC–25 kHz
Duty Cycle .............................................0%–100%
Logic Low State (Vmin–Vmax) .............0.0 to +0.8 VDC
Logic High State (Vmin–Vmax) ............+3.5 to +6.7 VDC
Cooling Specifications (Air-cooled) (Water-cooled)
Maximum Heat Load, Laser Head ................1150 Watts ...................................... 1150 Watts
, RF-1000 .....................1150 Watts ...................................... 1150 Watts
Minimum Flow Rate ......................................195 CFM per fan (×2, centered) .... 0.75–2.0 GPM, < 60 PSI
rear air-cooled .........................................N/A ................................................. N/A
Coolant Temperature ....................................< 40 °C, ambient ............................ 18–22 °C
* Specifications subject to change without notice.
Typical. Actual wavelength range may vary from 10.2–10.8 µm.
1 This power level is guaranteed for 12 months regardless of operating hours.
2 Minimum 30 VDC input voltage to obtain guaranteed output power.
3 With two-meter RF cable length.
4 From cold start (guaranteed).
5 Measured at laser output.
6 Tested at 5 kHz.