maintenance/
troubleshooting
414
Synrad Firestar t-Series operator’s manual
Troubleshooting
RF Drive DC fault
An RF Drive DC fault is indicated by the RDY indicator flashing 3 blinks. Reset the laser by
removing DC power to the RF power supply, wait 30 seconds, and then reapply DC power. If
the RF Drive DC fault reappears, contact SYNRAD or a SYNRAD Authorized Distributor.
PWM Drive fault
A PWM Drive fault is indicated by the RDY indicator flashing 4 blinks. Reset the laser by
removing DC power to the RF power supply, wait 30 seconds, and then reapply DC power. If
the PWM Drive fault reappears, contact SYNRAD or a SYNRAD Authorized Distributor.
RF Cable Interlock fault
An RF Cable Interlock fault occurs when the RF cable loses continuity (appears electrically
open). This fault is indicated by the RDY indicator flashing 5 blinks. Verify that the RF cable
is undamaged and that connectors on both the Laser Head and RF power supply are tight. To
reset an RF Cable Interlock fault, cycle DC power. When the RDY indicator illuminates, lasing
is enabled after a five-second delay.
Other laser faults
When a laser fault occurs, Firestar’s status LEDs and output signals will reflect a fault condition as indi-
cated in Tables 4-3–4-5 or Table 4-6 . Each Symptom listed below describes a particular fault. For each
Symptom, specific causes and solutions are described under Possible Causes.
Warning
serious
personal
injury
On Firestar t-Series OEM lasers, remote interlock (INT) faults are
not latched. Clearing the fault condition re-enables the RDY indica-
tor and the laser will fire after the five-second delay provided that the
SHT indicator is lit and a PWM Command signal is applied. Because
exposure to 10.6 µm CO
2
laser radiation can inflict severe corneal
injuries and seriously burn human tissue, the OEM or System Integra-
tor must ensure that appropriate safeguards are in place to prevent
unintended lasing.
Symptom:
A remote interlock fault is indicated:
INT LED – Red Interlock Open – Closed
TMP LED – Green Over Temperature Open
RDY LED – Off Laser Ready – Open
SHT LED – Blue Shutter Open – Closed
LASE LED – Off Laser Active – Open
Possible Causes:
No voltage applied to Pin 3 (Remote Interlock) of the User I/O connector.